86 independent product pages integrated into one catalog, each with Key Phrase / SEO Title / H1 / Slug / Meta / Image alt and body content.
Search by model, current, voltage, process or key phrase; filter by cooling method.
Electrocoagulation Wastewater Treatment Rectifier from Gaohui Rectifier powers compact electrode banks for on-site effluent treatment. In addition, this 50 A 36 V Electrocoagulation Wastewater Treatment Rectifier fits small-flow plants that prize stable floc formation. Therefore, operators trust the Electrocoagulation Wastewater Treatment Rectifier for consistent turbidity removal and metal precipitation. Furthermore, Gaohui Rectifier ships this model with air cooling, RS485 control, and a programmable output ramp. As a result, the rectifier reduces chemical dosing while keeping discharge limits within reach.
Textile dyeing plants use this rectifier to energize aluminum plates for color removal and COD reduction. For example, a 50 A output sustains a compact plate array that handles daily batches of a few dozen cubic meters. Moreover, the 36 V ceiling keeps operation safe in high-conductivity dye baths.
Food and dairy processors apply the same rectifier to break emulsified oils and settle suspended solids before flotation. In addition, electroplating rinse water benefits from the hydroxide flocs that capture dissolved copper and nickel. Consequently, one rectifier covers pretreatment, polishing, and emergency discharge duties within a small footprint.
| Output Current | 50 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Electrocatalytic Oxidation Rectifier from Gaohui Rectifier energizes dimensionally stable anodes for refractory COD destruction. In addition, this 50 A 36 V Electrocatalytic Oxidation Rectifier suits pilot cells and small batch reactors with limited electrode area. Therefore, chemists choose the Electrocatalytic Oxidation Rectifier for steady hydroxyl-radical generation without chemical dosing pumps. Furthermore, RS485 control allows remote setpoint changes while loads swing during batch cycles. As a result, this rectifier keeps oxidation current stable even when conductivity drifts.
Plating and surface-finishing shops use this rectifier to break cyanide complexes and oxidize organic brighteners. For example, a 50 A supply drives small titanium-anode cells that polish rinse water before discharge. Moreover, the 36 V level suits conductive process baths without stressing seals or linings.
Leachate and pharmaceutical plants run the same rectifier on advanced oxidation steps that target refractory COD. In addition, dye intermediate streams respond to the constant DC output that this model maintains. Consequently, plant chemists gain a compact oxidation tool that replaces part of their chemical oxidant budget.
| Output Current | 50 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
Electro-Fenton Rectifier from Gaohui Rectifier supplies controlled DC to electro-Fenton cells for advanced oxidation treatment. In addition, this 50 A 36 V Electro-Fenton Rectifier suits bench trials and compact treatment skids for high-strength wastewater. Therefore, engineers choose the Electro-Fenton Rectifier when they need steady current for ferrous regeneration and peroxide formation. Furthermore, Gaohui Rectifier builds this model with air cooling and a low-ripple output for dependable laboratory work.
Pharmaceutical manufacturers use this rectifier to oxidize recalcitrant organics in synthesis wastewater before biological polishing. For example, a 50 A output energizes small electrode pairs that maintain a steady Fenton reaction across the day. Moreover, the 36 V ceiling suits bench-scale cells and mobile treatment containers.
Leachate treatment plants apply the same rectifier on secondary effluent that still carries chemical oxygen demand. In addition, coking and dyeing facilities use it to pre-oxidize inhibitors that would otherwise stress downstream biology. Consequently, this rectifier delivers a compact electro-Fenton step without large power infrastructure.
| Output Current | 50 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electro-Fenton oxidation cells |
Electrolytic Descaling Rectifier from Gaohui Rectifier delivers controlled DC to descaling electrodes inside cooling water loops. In addition, this 30 A 36 V Electrolytic Descaling Rectifier suits mid-size recirculating systems that run at moderate conductivity. Therefore, plant engineers choose the Electrolytic Descaling Rectifier to hold calcium and silica deposits below nuisance levels. Furthermore, the air-cooled frame needs no cooling-water hookup, so it fits tight pump rooms. As a result, operators suppress tube fouling and keep heat transfer efficiency stable.
Cooling tower operators deploy this rectifier to feed sacrificial anode rods inside open recirculating loops. For example, a 30 A output maintains a steady descaling current across several dozen cooling tons of heat load. Moreover, the 36 V ceiling matches the low conductivity of treated make-up water without over-design.
Boiler and heat-exchange stations then rely on the same rectifier to inhibit scale growth on tube walls. In addition, deep-well hard-water systems use it to suppress calcium carbonate deposition on downstream fixtures. Consequently, service crews shut down less often for manual acid cleaning of heat-transfer surfaces.
| Output Current | 30 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrolytic descaling of hard-water circuits |
Automatic Periodic Reverse Rectifier from Gaohui Rectifier switches polarity on schedule to strip scale from high-voltage electrode stacks. In addition, this 50 A 1000 V Automatic Periodic Reverse Rectifier drives series-wired electrolytic cells that demand a tall voltage ceiling. Therefore, electrochemists pick the Automatic Periodic Reverse Rectifier when electrodes foul fast under viscous or high-resistivity feeds. Furthermore, the programmable dwell time balances anode and cathode wear across long campaigns. As a result, operators extend electrode service intervals without opening the cell for manual cleaning.
High-impedance electrolysis stacks use this rectifier to energize long strings of series-connected electrode pairs. For example, the 1000 V ceiling overcomes resistive brine or deionized water gaps that low-voltage models cannot reach. Moreover, the 50 A rating matches pilot and mid-size production cells rather than full-scale lines.
Descaling and electrocoagulation teams then adopt the same rectifier to shed scaling layers automatically. In addition, the reversal cycle peels off calcium-rich films that would otherwise insulate the plates. Consequently, maintenance crews spend fewer hours on acid baths and manual scraping of electrode surfaces.
| Output Current | 50 A (adjustable) |
|---|---|
| Output Voltage | 1000 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
Electrodialysis Rectifier from Gaohui Rectifier supplies smooth DC to membrane stacks for salt separation. In addition, this 100 A 100 V Electrodialysis Rectifier matches a typical pilot or small production electrodialysis skid. Therefore, water-treatment engineers choose the Electrodialysis Rectifier for brackish water and RO concentrate recovery duties. Furthermore, the low ripple output protects ion-exchange membranes from local overheating. As a result, desalination runs steadily while operators trim the applied voltage to feed salinity.
Brackish-water stations use this rectifier to drive small electrodialysis stacks that split salts from feedwater. For example, a 100 A output feeds a few membrane cell pairs arranged for a few cubic meters per hour. Moreover, the 100 V headroom accommodates multi-stage stacks in series.
RO concentrate recovery plants then adopt the same rectifier to reduce brine discharge volumes. In addition, cooling tower blowdown reuse projects rely on it to concentrate dissolved salts before disposal. Consequently, operators cut both brine hauling costs and fresh make-up demand.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 100 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrodialysis stack powering |
Single-Pulse Electrocoagulation Rectifier from Gaohui Rectifier delivers pulsed DC to plate arrays for denser floc formation. In addition, this 100 A 500 V Single-Pulse Electrocoagulation Rectifier suits high-impedance plate strings where steady DC would passivate fast. Therefore, treatment designers pick the Single-Pulse Electrocoagulation Rectifier for feeds that foul aluminum or iron electrodes quickly. Furthermore, the programmable pulse frequency lets engineers tune shear and charge density together. As a result, operators reduce electrode consumption while lifting turbidity and color removal.
Textile dyeing mills use this rectifier to pulse aluminum plate arrays for decolorization and COD trimming. For example, the 500 V ceiling energizes long series plate strings that treat moderate dye volumes continuously. Moreover, the pulsed current suppresses passive films that dull plain DC operation.
Plating rinse-water lines then adopt the same rectifier to flocculate dissolved copper and nickel. In addition, leachate pretreatment skids rely on it before biological stages kick in. Consequently, one rectifier covers decolorization, metal capture, and leachate conditioning in a compact footprint.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 500 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Application Duty | Electrocoagulation electrode arrays |
Single-Pulse Electrocatalytic Rectifier from Gaohui Rectifier pulses dimensionally stable anodes to break down refractory organics. In addition, this 400 A 50 V Single-Pulse Electrocatalytic Rectifier handles larger oxidation cells than bench-scale models. Therefore, process engineers choose the Single-Pulse Electrocatalytic Rectifier when anode passivation threatens long-run stability. Furthermore, the pulsed duty thins oxide layers so hydroxyl-radical production holds steady. As a result, plants oxidize persistent COD without choking on coated anodes.
Printed-circuit-board shops use this rectifier to pulse anode arrays that break metal-organic complexes in rinse water. For example, a 400 A output sustains a mid-size oxidation cell treating tens of cubic meters per shift. Moreover, the 50 V level fits conductive process baths without heavy insulation.
Dye and pharmaceutical intermediate factories then adopt the same rectifier to detoxify hard-to-biodegrade streams. In addition, recirculating cooling water systems use pulsed oxidation to suppress algae and biofilm growth. Consequently, operators trim downstream biological load and meet tighter discharge limits.
| Output Current | 400 A (adjustable) |
|---|---|
| Output Voltage | 50 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Application Duty | Electrocatalytic oxidation cells |
Sodium Hypochlorite Rectifier from Gaohui Rectifier feeds brine electrolysis cells that generate hypochlorite on site. In addition, this 200 A 24 V Sodium Hypochlorite Rectifier matches mid-size disinfection skids for water and wastewater plants. Therefore, utility engineers choose the Sodium Hypochlorite Rectifier when they want to replace delivered chlorine gas or bleach. Furthermore, the low-ripple DC keeps electrode efficiency high across the production shift. As a result, sites eliminate chemical transport hazards and dose disinfectant precisely.
Municipal and village water plants use this rectifier to power on-site brine electrolysis cells for drinking-water disinfection. For example, a 200 A output supports a mid-size skid that serves several thousand residents. Moreover, the 24 V class suits the low voltage of stacked electrolysis electrodes.
Wastewater treatment works then adopt the same rectifier to replace gaseous chlorine with generated hypochlorite. In addition, swimming-pool complexes rely on it for continuous low-level disinfection of recirculated water. Consequently, operators skip bulk chemical storage and tighten safety around the chlorination room.
| Output Current | 200 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Electrolysis Duty | Sodium hypochlorite generation cells |
Electrocoagulation Treatment Rectifier from Gaohui Rectifier powers small plate banks for pilot and laboratory electrocoagulation work. In addition, this 10 A 300 V Electrocoagulation Treatment Rectifier drives long series electrode strings across high-resistivity dilute feeds. Therefore, researchers pick the Electrocoagulation Treatment Rectifier when they need a tall voltage headroom with tiny current. Furthermore, the air-cooled cabinet suits bench rooms and mobile trial containers. As a result, teams run treatability studies without heavy plant wiring.
Plating and surface-finishing labs use this rectifier to energize small plate pairs that capture dissolved metals in rinse water. For example, the 300 V ceiling pushes current through high-resistivity dilute streams that low-voltage feeds cannot overcome. Moreover, the 10 A rating matches bench cells rather than production lines.
Textile treatability teams then adopt the same rectifier to test decolorization on small dye batches. In addition, leachate pilot skids rely on it to condition raw landfill liquor before scale-up trials. Consequently, engineers gather flocculation data with a compact, low-cost control cabinet.
| Output Current | 10 A (adjustable) |
|---|---|
| Output Voltage | 300 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Electrodialysis Reversing Rectifier from Gaohui Rectifier flips polarity on schedule to keep membrane stacks clean. In addition, this 20 A 18 V Electrodialysis Reversing Rectifier suits small EDR skids that treat scaling-prone brackish water. Therefore, desalination engineers choose the Electrodialysis Reversing Rectifier when gypsum or calcium carbonate threatens membrane surfaces. Furthermore, the automatic dwell cycle swaps concentrate and diluate channels in minutes. As a result, operators extend membrane life without acid cleaning stops.
Brackish-water villages use this rectifier to drive small EDR stacks that desalinate groundwater for drinking. For example, a 20 A output serves a compact skid producing a few cubic meters per day. Moreover, the 18 V level matches short membrane stacks with few cell pairs.
RO concentrate recovery pilots then adopt the same rectifier to test reversal duty on scaling feeds. In addition, cooling tower blowdown reuse trials rely on it to prevent gypsum fouling between cleanings. Consequently, researchers validate EDR operation before committing to a full-size plant.
| Output Current | 20 A (adjustable) |
|---|---|
| Output Voltage | 18 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
| Application Duty | Electrodialysis stack powering |
High-Voltage Single-Pulse Electrocoagulation Rectifier from Gaohui Rectifier pulses long plate strings that treat dilute, resistive feeds. In addition, this 30 A 500 V High-Voltage Single-Pulse Electrocoagulation Rectifier suits pilot arrays where a tall voltage beats low conductivity. Therefore, treatment designers pick the High-Voltage Single-Pulse Electrocoagulation Rectifier for feeds that resist ordinary low-voltage flocculation. Furthermore, the pulsed duty keeps plate surfaces active between reversal cycles. As a result, operators flocculate dilute streams with modest electrode area.
Dilute industrial effluent pilots use this rectifier to pulse long series plate strings at 500 V. For example, the high voltage pushes current through low-conductivity streams that stall at 36 V. Moreover, the 30 A rating matches mid-size bench-to-pilot plate banks.
Landfill leachate pretreatment teams then adopt the same rectifier to test flocculation on raw liquor. In addition, mining runoff trials rely on it to capture suspended solids before discharge. Consequently, engineers validate high-voltage electrocoagulation before scaling up.
| Output Current | 30 A (adjustable) |
|---|---|
| Output Voltage | 500 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Application Duty | Electrocoagulation electrode arrays |
Sodium Hypochlorite Generation Rectifier from Gaohui Rectifier powers small brine electrolysis cells for on-site chlorine generation. In addition, this 60 A 16 V Sodium Hypochlorite Generation Rectifier suits compact disinfection skids for small communities. Therefore, utility engineers choose the Sodium Hypochlorite Generation Rectifier when they want to skip delivered bleach deliveries. Furthermore, the low-ripple DC holds electrode efficiency steady through long duty cycles. As a result, small plants dose fresh hypochlorite without bulk chemical storage.
Village drinking-water stations use this rectifier to drive compact brine cells that generate low-concentration hypochlorite. For example, a 60 A output serves a small skid for a few hundred households. Moreover, the 16 V class matches short electrolysis electrode stacks.
Remote and emergency sites then adopt the same rectifier to avoid trucking chlorine to distant locations. In addition, seafood processing workshops rely on it for CIP sanitation disinfection. Consequently, operators cut chemical logistics and improve site safety.
| Output Current | 60 A (adjustable) |
|---|---|
| Output Voltage | 16 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Electrolysis Duty | Sodium hypochlorite generation cells |
Air-Cooled Electrolytic Descaling Rectifier from Gaohui Rectifier feeds small descaling electrodes in compact water circuits. In addition, this 10 A 36 V Air-Cooled Electrolytic Descaling Rectifier fits small cooling loops where no cooling water exists. Therefore, facilities engineers choose the Air-Cooled Electrolytic Descaling Rectifier for tight equipment rooms and rooftop cabinets. Furthermore, the fan-cooled cabinet needs zero water-side connections. As a result, operators suppress scale in small heat exchangers with a plug-and-play frame.
Small cooling-loop operators use this rectifier to feed anode rods in compact recirculating systems. For example, a 10 A output protects small heat exchangers and rooftop condenser circuits. Moreover, the 36 V ceiling matches low-conductivity treated make-up water.
Deep-well hard-water households then adopt the same rectifier to suppress scale on fixtures and geysers. In addition, small boiler feed systems rely on it to soften hard water without salt regenerators. Consequently, service crews extend the life of small heat-transfer hardware.
| Output Current | 10 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrolytic descaling of hard-water circuits |
Compact Electrolytic Descaling Rectifier from Gaohui Rectifier packs descaling power into a small, movable cabinet. In addition, this 10 A 36 V Compact Electrolytic Descaling Rectifier suits pilot carts and small hard-water circuits with limited space. Therefore, field engineers choose the Compact Electrolytic Descaling Rectifier when bench trials must move between sites. Furthermore, the light frame lifts by hand and plugs into a standard wall supply. As a result, teams test descaling chemistry without dedicating a fixed control room.
Mobile treatment carts use this rectifier to feed descaling electrodes at customer trial sites. For example, the 10 A output protects small heat exchangers during on-site demonstrations. Moreover, the 36 V class matches low-conductivity make-up water in compact loops.
Small drinking-water stations then adopt the same rectifier to suppress scale on point-of-use hardware. In addition, boiler feed systems rely on it for low-rate descaling without salt softeners. Consequently, operators test and run descaling duty in a single portable frame.
| Output Current | 10 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrolytic descaling of hard-water circuits |
Air-Cooled Single-Pulse Electrocoagulation Rectifier from Gaohui Rectifier pulses plate strings for high-voltage flocculation of dilute effluent. In addition, this 80 A 500 V Air-Cooled Single-Pulse Electrocoagulation Rectifier treats larger pilot-to-production arrays than 30 A class frames. Therefore, treatment designers pick the Air-Cooled Single-Pulse Electrocoagulation Rectifier when resistivity climbs and plate strings run long. Furthermore, the fan-cooled cabinet needs no water hookup. As a result, operators decolorize and settle dilute streams with stable pulsed current.
Municipal pretreatment pilots use this rectifier to pulse long plate strings at 500 V. For example, the high voltage drives series arrays through dilute wastewater that low-voltage frames stall on. Moreover, the 80 A rating matches mid-size pilot plate banks.
Landfill leachate teams then adopt the same rectifier to condition raw liquor before biological stages. In addition, mining runoff trials rely on it to flocculate suspended solids. Consequently, engineers validate high-voltage pulsed flocculation before scaling up.
| Output Current | 80 A (adjustable) |
|---|---|
| Output Voltage | 500 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Application Duty | Electrocoagulation electrode arrays |
Air-Cooled Sodium Hypochlorite Rectifier from Gaohui Rectifier drives brine electrolysis cells for on-site chlorine generation. In addition, this 100 A 14 V Air-Cooled Sodium Hypochlorite Rectifier serves compact disinfection skids for medium-size communities. Therefore, utility engineers choose the Air-Cooled Sodium Hypochlorite Rectifier when they replace delivered bleach with on-site generation. Furthermore, the fan-cooled cabinet needs no water-side cooling loop. As a result, plants dose fresh hypochlorite with a small, simple footprint.
Medium-size water plants use this rectifier to power brine cells that generate low-strength hypochlorite. For example, a 100 A output serves a skid for a few thousand residents. Moreover, the 14 V class matches short electrolysis electrode stacks.
Wastewater works then adopt the same rectifier to disinfect secondary effluent before discharge. In addition, food processing CIP stations rely on it for sanitation. Consequently, operators skip bulk bleach storage and hauling.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 14 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Electrolysis Duty | Sodium hypochlorite generation cells |
Single-Pulse Electrocoagulation Treatment Rectifier from Gaohui Rectifier pulses aluminum or iron plates for denser floc formation. In addition, this 100 A 36 V Single-Pulse Electrocoagulation Treatment Rectifier handles mid-size electrode banks for common conductive effluents. Therefore, treatment engineers pick the Single-Pulse Electrocoagulation Treatment Rectifier when they want stronger flocs than plain DC delivers. Furthermore, the adjustable duty ratio tunes shear to the target floc size. As a result, operators cut downstream settling tank load.
Textile dyeing mills use this rectifier to pulse plate arrays for decolorization of dye baths. For example, a 100 A output drives a mid-size bank treating tens of cubic meters per shift. Moreover, the 36 V level fits conductive dye wastewater without heavy insulation.
Food and dairy plants then adopt the same rectifier to break emulsified oils and settle solids. In addition, plating rinse lines rely on it to flocculate dissolved metals. Consequently, one rectifier covers decolorization, oil removal, and metal capture.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Application Duty | Electrocoagulation electrode arrays |
Air-Cooled Automatic Periodic Reverse Rectifier from Gaohui Rectifier swaps polarity on schedule to keep electrode surfaces clean. In addition, this 100 A 200 V Air-Cooled Automatic Periodic Reverse Rectifier suits mid-size electrolytic cells that foul under scaling feeds. Therefore, process engineers choose the Air-Cooled Automatic Periodic Reverse Rectifier when calcium films insulate plates between cleanings. Furthermore, the programmable dwell balances wear on both electrode sides. As a result, operators run longer campaigns without manual acid stripping.
Scaling electrocoagulation cells use this rectifier to reverse polarity and shed calcium-rich films in place. For example, the 200 V ceiling drives moderate series electrode strings at mid-size flow. Moreover, the 100 A rating matches a compact treatment skid.
Electrolytic descaling stations then adopt the same rectifier to peel cathode scale automatically. In addition, viscous-wastewater trials rely on reversal to keep plates active. Consequently, maintenance crews skip routine acid baths and scraping.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 200 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
Electrodialysis Auto-Reverse Rectifier from Gaohui Rectifier reverses polarity on schedule to protect membrane stacks from scale. In addition, this 100 A 300 V Electrodialysis Auto-Reverse Rectifier drives longer EDR stacks that need a tall voltage headroom. Therefore, desalination engineers choose the Electrodialysis Auto-Reverse Rectifier when scaling salts threaten continuous operation. Furthermore, the automatic dwell swaps concentrate and diluate flows without operator action. As a result, stacks run longer between acid cleanings.
Brackish-water utilities use this rectifier to drive mid-size EDR stacks that desalinate scaling groundwater. For example, the 300 V ceiling powers longer membrane strings with more cell pairs. Moreover, the 100 A rating matches a production skid for several cubic meters per hour.
RO concentrate recovery plants then adopt the same rectifier to cut brine volumes. In addition, cooling tower blowdown reuse relies on auto-reversal to prevent gypsum fouling. Consequently, operators shrink brine disposal costs and extend membrane life.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 300 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
| Application Duty | Electrodialysis stack powering |
Periodic-Reversing Electrolytic Descaling Rectifier from Gaohui Rectifier flips polarity to shed cathode scale in cooling-water loops. In addition, this 120 A 30 V Periodic-Reversing Electrolytic Descaling Rectifier serves industrial cooling systems with heavy fouling rates. Therefore, facilities engineers choose the Periodic-Reversing Electrolytic Descaling Rectifier when fixed-polarity rods foul within weeks. Furthermore, the reversal cycle balances wear on both electrode sides. As a result, operators suppress tube fouling and extend rod service life.
Industrial cooling towers use this rectifier to feed descaling rods that reverse polarity automatically. For example, a 120 A output protects larger loops serving several hundred cooling tons. Moreover, the 30 V level matches conductive recirculating water.
Heat-exchange stations then adopt the same rectifier to strip calcium scale from tube walls. In addition, deep-well hard-water systems rely on reversal to keep electrodes clean. Consequently, service crews cut acid cleaning stops to a minimum.
| Output Current | 120 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
| Application Duty | Electrolytic descaling of hard-water circuits |
Industrial Electrolytic Descaling Rectifier from Gaohui Rectifier feeds descaling electrodes in heavy-duty recirculating water systems. In addition, this 120 A 36 V Industrial Electrolytic Descaling Rectifier serves plant-wide cooling loops that run long duty cycles. Therefore, facilities engineers choose the Industrial Electrolytic Descaling Rectifier when scale threatens production heat exchangers. Furthermore, the air-cooled cabinet runs 24/7 without a cooling-water hookup. As a result, operators hold heat transfer efficiency steady across seasons.
Plant cooling systems use this rectifier to feed descaling rods across several cooling towers. For example, a 120 A output protects heat exchangers in a mid-size manufacturing site. Moreover, the 36 V ceiling matches treated make-up water conductivity.
Boiler and process water loops then adopt the same rectifier to inhibit scale on tube walls. In addition, deep-well hard-water supplies rely on it to suppress deposits. Consequently, service crews extend intervals between acid cleaning shutdowns.
| Output Current | 120 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrolytic descaling of hard-water circuits |
Air-Cooled Electrocatalytic Oxidation Rectifier from Gaohui Rectifier energizes DSA anodes for medium-flow oxidation lines. In addition, this 150 A 30 V Air-Cooled Electrocatalytic Oxidation Rectifier suits plating and textile effluent that demands steady hydroxyl generation. Therefore, engineers rely on the Air-Cooled Electrocatalytic Oxidation Rectifier to cut refractory COD without chemical dosing. Furthermore, Gaohui Rectifier builds the frame with forced air cooling and a low-ripple DC bus. As a result, the rectifier holds output current stable while bath conductivity drifts through batch cycles.
Plating and printed-circuit shops use this rectifier to break metal-cyanide complexes and oxidize brightener residues. For example, a 150 A output drives an anode stack that treats roughly 20–50 m³/h of rinse water. Moreover, the 30 V level matches conductive plating baths without overstressing coatings.
Dye and pharmaceutical producers apply the same rectifier to detoxify refractory intermediates before biological treatment. In addition, landfill leachate reverse flows benefit from steady advanced oxidation in a compact skid. Consequently, one rectifier covers pretreatment, polishing, and seasonal peak loads within a small plant room.
| Output Current | 150 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
Air-Cooled Sodium Hypochlorite Generation Rectifier from Gaohui Rectifier feeds brine electrolysis cells for on-site disinfection. In addition, this 150 A 36 V Air-Cooled Sodium Hypochlorite Generation Rectifier suits municipal and industrial chlorination that avoids chemical transport. Therefore, operators depend on the Air-Cooled Sodium Hypochlorite Generation Rectifier for steady hypochlorite output around the clock. Furthermore, Gaohui Rectifier packages it with forced air cooling and RS485 setpoint control. As a result, the rectifier cuts storage risks while keeping residual dosing stable.
Municipal water plants use this rectifier to power on-site brine electrolysis cells that replace bulk bleach deliveries. For example, a 150 A output sustains a mid-size generator feeding a few thousand cubic meters of treated water per day. Moreover, the 36 V ceiling suits low-voltage saltwater cells safely.
Seafood processing and pool operators apply the same rectifier for CIP sanitation and continuous residual dosing. In addition, wastewater treatment stations adopt it as a chlorine alternative where trucked chemicals pose safety risks. Consequently, one compact rectifier covers disinfection duties without on-site storage tanks.
| Output Current | 150 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Electrolysis Duty | Sodium hypochlorite generation cells |
Air-Cooled High-Voltage Single-Pulse Electrocoagulation Rectifier from Gaohui Rectifier drives series electrode banks through high-impedance water. In addition, this 150 A 500 V Air-Cooled High-Voltage Single-Pulse Electrocoagulation Rectifier suits dilute effluent that ordinary low-voltage cells cannot reach. Therefore, designers choose the Air-Cooled High-Voltage Single-Pulse Electrocoagulation Rectifier to stack plates in series and cut busbar runs. Furthermore, Gaohui Rectifier builds it with programmable pulse frequency and duty ratio. As a result, the rectifier suppresses electrode passivation and produces denser flocs.
Dilute textile and mining effluents use this rectifier to energize long series plate stacks where conductivity stays low. For example, the 500 V output pushes current through dozens of plates wired in series, trimming heavy copper busbars. Moreover, pulse modulation keeps aluminum and iron surfaces active between cycles.
Leachate pretreatment plants apply the same rectifier to break colloids before downstream biological steps. In addition, low-conductivity surface water polishing benefits from the high-voltage reach that short electrode banks cannot deliver. Consequently, one rectifier handles dilute flows that demand voltage rather than raw current.
| Output Current | 150 A (adjustable) |
|---|---|
| Output Voltage | 500 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Application Duty | Electrocoagulation electrode arrays |
Sodium Hypochlorite Disinfection Rectifier from Gaohui Rectifier supplies on-site generators with steady low-voltage DC. In addition, this 160 A 36 V Sodium Hypochlorite Disinfection Rectifier replaces trucked bleach for routine disinfection duties. Therefore, plant managers rely on the Sodium Hypochlorite Disinfection Rectifier to cut chemical inventory and storage risk. Furthermore, Gaohui Rectifier outfits it with air cooling and RS485 control. As a result, the rectifier maintains consistent hypochlorite strength across daily demand swings.
Swimming pools and water parks use this rectifier to power salt-chlorination cells that keep residual chlorine steady. For example, a 160 A output sustains mid-size pool systems without liquid bleach storage rooms. Moreover, the 36 V class keeps contact voltage low for public facilities.
Rural water stations and seafood plants apply the same rectifier for decentralized disinfection. In addition, small municipal works adopt it to eliminate chlorine gas cylinders on site. Consequently, operators gain safer chemistry with a compact air-cooled footprint.
| Output Current | 160 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Electrolysis Duty | Sodium hypochlorite generation cells |
Air-Cooled Electrocoagulation Rectifier from Gaohui Rectifier energizes plate arrays for mid-range effluent treatment. In addition, this 200 A 24 V Air-Cooled Electrocoagulation Rectifier suits food, dairy, and metal-finishing streams that need bulk flocculation. Therefore, operators trust the Air-Cooled Electrocoagulation Rectifier to settle emulsified oils and suspended solids reliably. Furthermore, Gaohui Rectifier builds it with forced air cooling and a low-ripple output. As a result, the rectifier cuts coagulant dosing while holding discharge limits within reach.
Food and dairy processors use this rectifier to break emulsified fats and settle suspended solids before flotation. For example, a 200 A output drives a plate bank that treats tens of cubic meters per hour of rinse water. Moreover, the 24 V level matches high-conductivity wash baths without heavy insulation.
Electroplating shops apply the same rectifier to hydroxide-floc copper, nickel, and zinc from rinse streams. In addition, textile mills use it to drop color and COD loads ahead of biological polishing. Consequently, one rectifier covers pretreatment across several production lines.
| Output Current | 200 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Industrial Electrocatalytic Oxidation Rectifier from Gaohui Rectifier powers high-voltage DSA stacks for stubborn waste streams. In addition, this 250 A 120 V Industrial Electrocatalytic Oxidation Rectifier suits lower-conductivity effluent that demands voltage headroom. Therefore, engineers choose the Industrial Electrocatalytic Oxidation Rectifier to reach advanced-oxidation targets without oversized cells. Furthermore, Gaohui Rectifier builds it with air cooling and programmable output ramps. As a result, the rectifier holds hydroxyl generation steady as bath resistivity rises.
Landfill leachate plants use this rectifier to drive high-voltage anode stacks that oxidize refractory COD. For example, the 120 V reach pushes current through lower-conductivity concentrate that low-voltage cells cannot energize. Moreover, the 250 A output supports continuous treatment of several tens of cubic meters per day.
Chemical-park and oilfield operators apply the same rectifier for tail-end discharge upgrades. In addition, circulating water systems benefit from its bactericidal oxidation during hot seasons. Consequently, one rectifier covers polishing, sterilization, and emergency effluent duties.
| Output Current | 250 A (adjustable) |
|---|---|
| Output Voltage | 120 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
Electrocatalytic Auto-Reversing Rectifier from Gaohui Rectifier switches polarity automatically to keep oxidation anodes clean. In addition, this 300 A ±12 V Electrocatalytic Auto-Reversing Rectifier suits conductive wastewater where fouling and scale otherwise passivate surfaces. Therefore, operators rely on the Electrocatalytic Auto-Reversing Rectifier to extend electrode service life without manual scraping. Furthermore, Gaohui Rectifier builds it with adjustable reversal periods and dwell times. As a result, the rectifier maintains steady current across weeks of continuous run.
Plating and printed-circuit shops use this rectifier to run oxidation cells that would otherwise foul with scale. For example, the ±12 V bipolar output flips polarity on schedule, stripping deposits from both electrode sides. Moreover, the 300 A class handles mid-size lines that run around the clock.
Circulating cooling water systems apply the same rectifier to suppress biofilm and mineral buildup on anode surfaces. In addition, metal-finishing rinse streams benefit from self-cleaning cycles that reduce manual maintenance. Consequently, one rectifier keeps oxidation performance stable without frequent electrode pulls.
| Output Current | 300 A (adjustable) |
|---|---|
| Output Voltage | ±12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
| Application Duty | Electrocatalytic oxidation cells |
Electrolytic Descaling Water Treatment Rectifier from Gaohui Rectifier feeds anti-scale cells for hard-water circuits. In addition, this 300 A 36 V Electrolytic Descaling Water Treatment Rectifier suits cooling towers and heat exchangers that fight calcium fouling. Therefore, plant engineers choose the Electrolytic Descaling Water Treatment Rectifier to cut chemical acid cleaning. Furthermore, Gaohui Rectifier builds it with air cooling and robust DC busbars. As a result, the rectifier keeps heat-transfer surfaces clean with minimal dosing.
Cooling towers and circulating loops use this rectifier to drive electrolytic anti-scale cells that precipitate calcium out of solution. For example, a 300 A output protects heat exchangers serving several hundred tons of cooling capacity. Moreover, the 36 V class matches cell voltage for safe, efficient operation.
Boiler make-up and hard-well water systems apply the same rectifier to inhibit scale on pipe walls. In addition, food and beverage plants use it to descale CIP loops without harsh acids. Consequently, one rectifier cuts cleaning downtime and water-treatment chemical costs.
| Output Current | 300 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrolytic descaling of hard-water circuits |
Electrocoagulation Phosphorus Removal Rectifier from Gaohui Rectifier energizes series plate banks for municipal phosphorus polishing. In addition, this 300 A 220 V Electrocoagulation Phosphorus Removal Rectifier suits plants that push dissolved phosphate below tight discharge limits. Therefore, operators choose the Electrocoagulation Phosphorus Removal Rectifier to reach low-total-phosphorus targets without extra chemicals. Furthermore, Gaohui Rectifier builds it with high-voltage headroom and air cooling. As a result, the rectifier drives high-impedance electrode groups efficiently.
Municipal wastewater plants use this rectifier to drive series aluminum or iron plate arrays that precipitate dissolved phosphate. For example, the 220 V output energizes long stacks where cell resistance stays high, cutting heavy busbars. Moreover, the 300 A class supports a mid-size treatment line of several thousand cubic meters per day.
Food and dairy plants apply the same rectifier to remove phosphate from process streams before discharge. In addition, tertiary polishing steps benefit from its consistent metal-ion release for floc formation. Consequently, one rectifier covers both municipal and industrial phosphorus-abatement duties.
| Output Current | 300 A (adjustable) |
|---|---|
| Output Voltage | 220 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Air-Cooled Auto-Reverse Sodium Hypochlorite Rectifier from Gaohui Rectifier powers high-output brine cells with built-in polarity reversal. In addition, this 360 A 80 V Air-Cooled Auto-Reverse Sodium Hypochlorite Rectifier suits large disinfection stations that need steady generation and self-cleaning cells. Therefore, operators rely on the Air-Cooled Auto-Reverse Sodium Hypochlorite Rectifier to keep hypochlorite strength high without frequent acid washes. Furthermore, Gaohui Rectifier builds it with adjustable reversal cycles and air cooling. As a result, the rectifier runs long service intervals between electrode maintenance.
Large wastewater treatment plants use this rectifier to power high-output hypochlorite generators for contact-disinfection duty. For example, the 360 A output feeds mid-to-large cell arrays that replace bulk chlorine gas on site. Moreover, the 80 V class suits multi-cell stacks wired in series.
Industrial cooling water and seafood processing plants apply the same rectifier for continuous on-site sanitization. In addition, the automatic reversal cycles strip calcium scale from cell electrodes between runs. Consequently, operators gain consistent hypochlorite output with minimal manual cleaning.
| Output Current | 360 A (adjustable) |
|---|---|
| Output Voltage | 80 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
| Electrolysis Duty | Sodium hypochlorite generation cells |
High-Current Sodium Hypochlorite Rectifier from Gaohui Rectifier supplies large brine electrolysis generators with steady DC. In addition, this 380 A 80 V High-Current Sodium Hypochlorite Rectifier suits municipal and industrial stations that replace bulk chlorine on site. Therefore, plant managers choose the High-Current Sodium Hypochlorite Rectifier to meet high disinfection demand without chemical trucks. Furthermore, Gaohui Rectifier builds it with air cooling and reinforced DC busbars. As a result, the rectifier holds hypochlorite output stable across peak demand.
Municipal water treatment plants use this rectifier to power high-capacity brine generators feeding large distribution systems. For example, the 380 A output sustains generators that replace hundreds of kilograms of bulk bleach per day. Moreover, the 80 V class drives series multi-cell stacks without excessive busbar runs.
Power-plant and industrial cooling systems apply the same rectifier for continuous biofilm control. In addition, large seafood and beverage plants use it for on-site CIP sanitization at scale. Consequently, one rectifier covers high-demand disinfection across several processes.
| Output Current | 380 A (adjustable) |
|---|---|
| Output Voltage | 80 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Electrolysis Duty | Sodium hypochlorite generation cells |
Dual-Output Electrocatalytic Rectifier from Gaohui Rectifier drives two independent oxidation cells from one cabinet. In addition, this 400 A 10 V Dual-Output Electrocatalytic Rectifier lets operators set separate currents for two treatment stages. Therefore, engineers choose the Dual-Output Electrocatalytic Rectifier to cut cabinet count and plant-room footprint. Furthermore, Gaohui Rectifier builds it with two isolated channels and RS485 dual-channel control. As a result, the rectifier runs staged oxidation trains with independent setpoints.
Plating and printed-circuit shops use this rectifier to run a two-stage oxidation train from one frame. For example, one channel treats rinse water while the other polishes concentrate, each with its own current setpoint. Moreover, the 10 V class matches conductive cells without heavy insulation.
Leachate and chemical-park plants apply the same rectifier for staged oxidation that targets different COD fractions. In addition, separate channels let operators tune each stage to its own electrode area. Consequently, one rectifier replaces two cabinets and simplifies plant wiring.
| Output Current | 400 A (adjustable) |
|---|---|
| Output Voltage | 10 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU (Dual Channel) |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Output Channels | Two independent channels with separate setpoints |
| Application Duty | Electrocatalytic oxidation cells |
Air-Cooled Electrocatalytic Rectifier from Gaohui Rectifier drives high-current DSA cells for industrial oxidation lines. In addition, this 500 A 12 V Air-Cooled Electrocatalytic Rectifier suits conductive wastewater that demands bulk current rather than voltage. Therefore, operators choose the Air-Cooled Electrocatalytic Rectifier to scale oxidation treatment to continuous production. Furthermore, Gaohui Rectifier builds it with forced air cooling and low-ripple DC output. As a result, the rectifier holds current stable across large electrode banks.
Plating and circuit-board shops use this rectifier to power high-current anode stacks that break complex organics at scale. For example, the 500 A output feeds large DSA arrays treating several tens of cubic meters per hour. Moreover, the 12 V class matches highly conductive process baths efficiently.
Chemical-park and dyeing plants apply the same rectifier for tail-end COD polishing on continuous lines. In addition, oilfield produced-water systems benefit from its high-current oxidation during peak flows. Consequently, one rectifier scales to industrial duty without extra cabinets.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
Electroflotation Rectifier from Gaohui Rectifier generates fine hydrogen and oxygen bubbles for flotation cells. In addition, this 500 A 12 V Electroflotation Rectifier suits oil, grease, and suspended-solid separation at industrial scale. Therefore, operators rely on the Electroflotation Rectifier to replace dissolved-air flotation with simpler chemical-free equipment. Furthermore, Gaohui Rectifier builds it with air cooling and robust busbars. As a result, the rectifier drives dense micro-bubble generation around the clock.
Slaughterhouses and food processors use this rectifier to drive electroflotation cells that skim fats, oils, and grease. For example, the 500 A output feeds micro-bubble electrodes separating tens of cubic meters per hour. Moreover, the 12 V class matches conductive waste streams efficiently.
Petrochemical and refinery plants apply the same rectifier as a chemical-free alternative to dissolved-air flotation. In addition, municipal primary treatment lines benefit from its compact footprint and rapid startup. Consequently, one rectifier handles oily and greasy effluent without compressed-air systems.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electroflotation cell arrays |
Electrocoagulation Water Treatment Rectifier from Gaohui Rectifier energizes large plate arrays for bulk flocculation duty. In addition, this 500 A 12 V Electrocoagulation Water Treatment Rectifier suits high-conductivity effluent that demands heavy current. Therefore, operators choose the Electrocoagulation Water Treatment Rectifier to scale pretreatment to industrial flows. Furthermore, Gaohui Rectifier builds it with forced air cooling and reinforced DC busbars. As a result, the rectifier drives large electrode banks continuously.
Food and dairy plants use this rectifier to drive large plate banks that break emulsified fats at high flow. For example, the 500 A output energizes arrays treating tens of cubic meters per hour of rinse water. Moreover, the 12 V class matches highly conductive wash baths efficiently.
Electroplating and metal-finishing shops apply the same rectifier to hydroxide-floc heavy metals from large rinse streams. In addition, textile mills use it to drop color and COD across continuous production. Consequently, one rectifier covers high-throughput pretreatment across several lines.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Air-Cooled Electrocoagulation Wastewater Rectifier from Gaohui Rectifier powers mid-voltage plate arrays for industrial effluent. In addition, this 500 A 18 V Air-Cooled Electrocoagulation Wastewater Rectifier suits streams that need a little more voltage than plain conductive wash water. Therefore, operators choose the Air-Cooled Electrocoagulation Wastewater Rectifier to handle mixed industrial flows. Furthermore, Gaohui Rectifier builds it with forced air cooling and low ripple. As a result, the rectifier drives plate banks steadily across variable loads.
Mixed industrial parks use this rectifier to drive plate arrays that flocculate combined wastewater from several trades. For example, the 18 V headroom pushes current through less-conductive streams that plain 12 V cells struggle with. Moreover, the 500 A class supports continuous flows of several tens of cubic meters per hour.
Tannery and leather plants apply the same rectifier to settle chromium and organic load before biological treatment. In addition, landfill leachate pretreatment benefits from its robust floc formation. Consequently, one rectifier handles variable mixed effluent without frequent retuning.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 18 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Air-Cooled Electrocoagulation Treatment Rectifier from Gaohui Rectifier drives mid-voltage plate arrays for versatile effluent treatment. In addition, this 500 A 24 V Air-Cooled Electrocoagulation Treatment Rectifier suits mixed industrial streams that need moderate voltage headroom. Therefore, operators choose the Air-Cooled Electrocoagulation Treatment Rectifier for robust flocculation across variable wastewater. Furthermore, Gaohui Rectifier builds it with air cooling and a programmable output ramp. As a result, the rectifier holds floc formation steady as loads swing.
Automotive and parts-washing plants use this rectifier to drive plate arrays that flocculate oil and metal fines from rinse water. For example, the 24 V headroom pushes current through moderately conductive wash baths. Moreover, the 500 A class supports continuous flows of several tens of cubic meters per hour.
Mixed industrial parks apply the same rectifier for combined effluent that varies across shifts. In addition, metal-finishing shops benefit from its heavy-metal flocculation before discharge. Consequently, one rectifier covers variable pretreatment without frequent retuning.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Rack-Mounted Electrocatalytic Rectifier from Gaohui Rectifier mounts five modules on one shared rack for oxidation duty. In addition, this 500 A 26 V Rack-Mounted Electrocatalytic Rectifier consolidates cabling and saves plant-room floor space. Therefore, engineers choose the Rack-Mounted Electrocatalytic Rectifier to scale oxidation lines with modular redundancy. Furthermore, Gaohui Rectifier ties the modules to a common reinforced DC busbar. As a result, the rack delivers balanced current across large anode stacks.
Chemical-park plants use this rack to power large DSA oxidation trains that treat high-COD effluent around the clock. For example, five 500 A modules share one busbar and split load across a big electrode array. Moreover, the 26 V class matches series cell stacks efficiently.
Pharmaceutical and dyeing factories apply the same rack for tail-end advanced oxidation on continuous lines. In addition, modular layout lets operators add capacity as flows grow. Consequently, one rack covers expansion without rebuilding the whole power train.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 26 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Configuration | 5 rectifier modules on a shared rack |
| DC Bus | Common reinforced busbar |
| Application Duty | Electrocatalytic oxidation cells |
Pulse Automatic Reverse Rectifier from Gaohui Rectifier combines high-frequency pulsing with automatic polarity reversal. In addition, this 500 A 48 V Pulse Automatic Reverse Rectifier suits sticky or fouling-prone electrochemical systems. Therefore, operators rely on the Pulse Automatic Reverse Rectifier to keep electrodes clean and active without manual scraping. Furthermore, Gaohui Rectifier builds it with adjustable pulse and reversal timing. As a result, the rectifier sustains steady current through hard-to-treat effluent.
Electrochemical treatment of viscous and sticky effluents uses this rectifier to pulse current while reversing polarity on schedule. For example, the 48 V output drives mid-size stacks that foul rapidly under plain DC. Moreover, combined pulsing and reversal keeps both electrode sides clean.
Metal-finishing and recycling plants apply the same rectifier to sludge-prone streams that would otherwise passivate electrodes. In addition, high-voltage headroom reaches series cell arrays where plain low-voltage cells fail. Consequently, one rectifier handles fouling systems that demand both pulse and auto-reverse.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 48 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
High-Current Air-Cooled Electrocoagulation Rectifier from Gaohui Rectifier drives high-voltage plate arrays for demanding effluent. In addition, this 500 A 50 V High-Current Air-Cooled Electrocoagulation Rectifier suits less-conductive streams that demand both current and voltage headroom. Therefore, operators choose the High-Current Air-Cooled Electrocoagulation Rectifier to treat dilute or complex wastewater. Furthermore, Gaohui Rectifier builds it with air cooling and reinforced busbars. As a result, the rectifier sustains floc formation across a wide conductivity range.
Mining and mineral-processing plants use this rectifier to drive series plate stacks through dilute effluent where conductivity stays low. For example, the 50 V headroom pushes current through long plate arrays, trimming heavy busbars. Moreover, the 500 A class supports continuous flows of several tens of cubic meters per hour.
Landfill leachate pretreatment and mixed industrial parks apply the same rectifier for complex dilute streams. In addition, dye and textile mills benefit from its high-voltage reach for color removal. Consequently, one rectifier handles effluent that plain low-voltage cells cannot energize.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 50 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Air-Cooled Electrocoagulation Water Treatment Rectifier from Gaohui Rectifier energizes extra-large plate banks for heavy-duty effluent. In addition, this 600 A 15 V Air-Cooled Electrocoagulation Water Treatment Rectifier suits high-conductivity streams that demand maximum current. Therefore, operators choose the Air-Cooled Electrocoagulation Water Treatment Rectifier to scale pretreatment past the 500 A class. Furthermore, Gaohui Rectifier builds it with forced air cooling and reinforced busbars. As a result, the rectifier drives oversized electrode banks continuously.
Large food and dairy plants use this rectifier to drive oversized plate banks that break emulsified fats at very high flow. For example, the 600 A output energizes arrays treating well over fifty cubic meters per hour. Moreover, the 15 V class matches highly conductive wash baths efficiently.
Automotive and industrial-park operators apply the same rectifier for bulk pretreatment across multiple production lines. In addition, metal-finishing shops benefit from its heavy-metal flocculation at scale. Consequently, one rectifier handles the biggest pretreatment duties in a compact air-cooled frame.
| Output Current | 600 A (adjustable) |
|---|---|
| Output Voltage | 15 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Air-Cooled High-Current Electrocatalytic Rectifier from Gaohui Rectifier drives large DSA stacks for heavy oxidation duty. In addition, this 750 A 24 V Air-Cooled High-Current Electrocatalytic Rectifier suits industrial lines that need bulk current with moderate voltage headroom. Therefore, operators choose the Air-Cooled High-Current Electrocatalytic Rectifier to scale advanced oxidation to large flows. Furthermore, Gaohui Rectifier builds it with air cooling and reinforced DC busbars. As a result, the rectifier holds output steady across continuous 24/7 runs.
Large chemical-park plants use this rectifier to power big DSA stacks that oxidize refractory COD on continuous lines. For example, the 750 A output feeds large anode arrays treating several tens of cubic meters per hour. Moreover, the 24 V class matches series cell stacks efficiently.
Pharmaceutical and landfill-leachate operators apply the same rectifier for tail-end advanced oxidation at scale. In addition, dyeing mills benefit from its high-current polishing of color and COD loads. Consequently, one rectifier covers the biggest oxidation trains without extra cabinets.
| Output Current | 750 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
Air-Cooled Sodium Hypochlorite DC Rectifier from Gaohui Rectifier powers on-site brine electrolysis cells for drinking water and wastewater disinfection. In addition, this 800 A 36 V Air-Cooled Sodium Hypochlorite DC Rectifier matches large municipal chlorine demand without chemical transport. Consequently, operators rely on the Air-Cooled Sodium Hypochlorite DC Rectifier to feed continuous low-dose sodium hypochlorite into contact tanks. Furthermore, Gaohui Rectifier tunes the output ramp to protect titanium electrode plates from inrush current. As a result, plants reduce bulk chlorine storage and keep disinfection residuals stable across 24/7 operation.
Municipal water plants deploy this rectifier to energize bipolar titanium cells that generate dilute sodium hypochlorite from brine. For example, an 800 A output sustains large banks serving tens of thousands of residents. Moreover, the 36 V class stays safe for submerged service in wet electrolysis rooms.
Wastewater treatment stations replace bulk chlorine gas with the same rectifier, dosing contact chambers continuously. In addition, seafood and aquatic processors run on-site brine electrolysis for CIP sanitization lines. Consequently, remote sites skip chemical delivery trucks and stock only common salt.
| Output Current | 800 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Electrolysis Duty | Sodium hypochlorite generation cells |
High-Current Automatic Periodic Reverse Rectifier from Gaohui Rectifier drives large electrolytic cells where fouling and scaling would otherwise stop production. In addition, this 1000 A 10 V High-Current Automatic Periodic Reverse Rectifier swaps polarity on a programmable cycle to strip cathode scale. Consequently, operators keep electrode gaps stable without manual scraping or acid washes. Furthermore, Gaohui Rectifier builds the reverse contactor with reinforced busbars for repeated high-current switching. As a result, the High-Current Automatic Periodic Reverse Rectifier sustains continuous operation in descaling, electrocoagulation, and metal recovery lines.
Cooling tower and circulating water systems use this rectifier to suppress calcium and silica scale on cathode surfaces. For example, a 1000 A output feeds large electrode arrays handling hundreds of cubic meters per hour. Moreover, the 10 V class matches highly conductive tap water with minimal line loss.
Electrocoagulation and metal recovery cells benefit from automatic reversal that strips deposited hydroxide sludge. In addition, electroplating rinse lines run periodic reverse to keep cathode plates free of dense copper and nickel scale. Consequently, plant crews extend plate service intervals and cut chemical cleaning cycles.
| Output Current | 1000 A (adjustable) |
|---|---|
| Output Voltage | 10 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
Air-Cooled Electro-Fenton Rectifier from Gaohui Rectifier supplies large advanced-oxidation cells with the current density needed for hydroxyl radical generation. In addition, this 1000 A 18 V Air-Cooled Electro-Fenton Rectifier supports on-site H₂O₂ production at the cathode, cutting external chemical dosing. Consequently, operators target refractory COD in leachate, coking, and pharma effluents. Furthermore, Gaohui Rectifier holds ripple under 2% to keep Fe²⁺ catalytic cycles stable. As a result, the Air-Cooled Electro-Fenton Rectifier delivers consistent oxidation across high-volume treatment lines.
Pharmaceutical plants run this rectifier on hard-to-biodegrade COD streams that follow biological treatment. For example, a 1000 A output drives large graphite cathode arrays in continuous-flow oxidation reactors. Moreover, the 18 V ceiling matches typical Fenton cell gaps under acidic pH.
Landfill leachate polishing and coking wastewater pretreatment also use the same rectifier to mineralize refractory aromatics. In addition, dyeing mills apply electro-Fenton as a final color and COD safety barrier before discharge. Consequently, plants avoid hauling hazardous concentrated peroxide and keep reagent inventory low.
| Output Current | 1000 A (adjustable) |
|---|---|
| Output Voltage | 18 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electro-Fenton oxidation cells |
Electrocatalytic Oxidation Drive Rectifier from Gaohui Rectifier drives large dimensionally stable anode (DSA) reactors in continuous wastewater treatment. In addition, this 1000 A 24 V Electrocatalytic Oxidation Drive Rectifier carries a 24/7 continuous duty rating built for unattended plant operation. Consequently, engineers use it on chemical park terminal polishing and printed-circuit-board effluent lines. Furthermore, Gaohui Rectifier reinforces the copper busbar to handle sustained high current without hot spots. As a result, the Electrocatalytic Oxidation Drive Rectifier keeps oxidation current stable across multi-shift production.
Printed circuit board and plating plants deploy this rectifier to break metal-cyanide complexes and lower terminal COD. For example, a 1000 A output feeds DSA anode plates in continuous-flow oxidation cells. Moreover, the 24 V class matches multi-stage electrode stacks typical of high-conductivity rinse water.
Chemical park end-of-pipe polishing and landfill leachate concentrate treatment also run the same rectifier. In addition, oilfield produced-water reuse lines use it to kill bacteria and oxidize residual hydrocarbons. Consequently, plant operators meet strict discharge limits without adding large chemical oxidation systems.
| Output Current | 1000 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU + HMI touch panel |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Duty Rating | Continuous 24/7 drive duty |
| DC Bus | Reinforced copper busbar |
High-Current Single-Pulse Electrocoagulation Rectifier from Gaohui Rectifier drives large plate arrays with pulsed current that reduces electrode passivation. In addition, this 1000 A 24 V High-Current Single-Pulse Electrocoagulation Rectifier suits high-volume textile, food, and metal finishing effluent lines. Consequently, operators get denser flocs and longer plate service life than with DC-only supply. Furthermore, Gaohui Rectifier sets pulse frequency and duty ratio through RS485 to match water chemistry. As a result, the High-Current Single-Pulse Electrocoagulation Rectifier cuts sludge volume while holding discharge targets.
Textile dyeing mills use this rectifier to energize aluminum and iron plate arrays for color stripping and COD reduction. For example, a 1000 A output sustains large banks treating dozens of cubic meters per hour. Moreover, the 24 V class matches highly conductive dye bath water with low resistive loss.
Food and dairy processors apply the same rectifier to break emulsified oils and settle suspended solids before flotation. In addition, electroplating rinse water benefits from pulsed flocs that capture dissolved copper and nickel. Consequently, one rectifier covers pretreatment, polishing, and emergency discharge duties on a continuous line.
| Output Current | 1000 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Pulse Frequency | 1–10 kHz (adjustable) |
| Pulse Duty Ratio | 10–90% (adjustable) |
| Application Duty | Electrocoagulation electrode arrays |
High-Current Electrocoagulation Rectifier from Gaohui Rectifier drives large plate banks for continuous industrial effluent treatment. In addition, this 1200 A 24 V High-Current Electrocoagulation Rectifier suits textile, food, and metal finishing lines that demand steady output. Consequently, operators scale floc formation without splitting current across multiple smaller rectifiers. Furthermore, Gaohui Rectifier keeps ripple below 2% so plate dissolution stays uniform. As a result, the High-Current Electrocoagulation Rectifier delivers consistent turbidity and metal removal across 24/7 production.
Textile dyeing plants deploy this rectifier to energize large aluminum and iron plate arrays for color removal. For example, a 1200 A output sustains banks treating tens of cubic meters per hour. Moreover, the 24 V class matches highly conductive dye bath water with low resistive loss.
Food and dairy processors apply the same rectifier to break emulsified oils and settle suspended solids. In addition, electroplating rinse water benefits from hydroxide flocs that capture dissolved copper and nickel. Consequently, one rectifier covers pretreatment, polishing, and emergency discharge duties on a continuous line.
| Output Current | 1200 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
High-Current Electrocatalytic Oxidation Rectifier from Gaohui Rectifier powers large DSA anode cells for terminal COD and ammonia removal. In addition, this 1500 A 15 V High-Current Electrocatalytic Oxidation Rectifier matches high-conductivity effluent with low resistive loss. Consequently, engineers deploy it on chemical park end-of-pipe and landfill leachate concentrate lines. Furthermore, Gaohui Rectifier reinforces the DC busbar for sustained high-current duty. As a result, the High-Current Electrocatalytic Oxidation Rectifier holds oxidation current stable across multi-shift operation.
Chemical park end-of-pipe polishing stations use this rectifier to degrade residual COD before discharge. For example, a 1500 A output feeds large DSA anode stacks treating hundreds of cubic meters per hour. Moreover, the 15 V class suits highly saline wastewater with high conductivity.
Landfill leachate concentrate and printed-circuit-board effluent also run the same rectifier for complex organic destruction. In addition, oilfield produced-water reuse lines apply it to oxidize residual hydrocarbons and control bacteria. Consequently, plants meet strict discharge limits without adding large chemical oxidation systems.
| Output Current | 1500 A (adjustable) |
|---|---|
| Output Voltage | 15 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
Industrial Electrocoagulation Rectifier from Gaohui Rectifier powers large plate arrays for continuous heavy effluent treatment. In addition, this 1500 A 24 V Industrial Electrocoagulation Rectifier serves municipal pretreatment and industrial high-flow lines alike. Consequently, operators scale floc formation without stacking multiple smaller rectifiers in parallel. Furthermore, Gaohui Rectifier holds ripple below 2% for uniform plate dissolution. As a result, the Industrial Electrocoagulation Rectifier delivers consistent turbidity, oil, and metal removal across 24/7 operation.
Municipal wastewater pretreatment plants deploy this rectifier to drive large aluminum and iron plate banks for phosphorus and turbidity reduction. For example, a 1500 A output sustains arrays treating hundreds of cubic meters per hour. Moreover, the 24 V class matches typical plate gaps in high-flow channels.
Food, dairy, and slaughterhouses apply the same rectifier to break emulsified fats and settle suspended solids. In addition, metal finishing rinse water benefits from hydroxide flocs that capture dissolved nickel, copper, and zinc. Consequently, one rectifier covers primary, secondary, and emergency discharge duties on a continuous line.
| Output Current | 1500 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Automatic Reverse Rectifier from Gaohui Rectifier drives high-current electrolytic cells where scale and fouling threaten continuous operation. In addition, this 2000 A 10 V Automatic Reverse Rectifier swaps polarity on a programmable cycle to strip cathode deposits. Consequently, operators keep electrode gaps stable without manual scraping or acid baths. Furthermore, Gaohui Rectifier builds the reverse contactor with reinforced busbars for repeated high-current switching. As a result, the Automatic Reverse Rectifier sustains continuous operation in descaling, electrocoagulation, and metal recovery lines.
Large cooling tower and circulating water systems use this rectifier to suppress calcium and silica scale on cathode surfaces. For example, a 2000 A output feeds electrode arrays handling thousands of cubic meters per hour. Moreover, the 10 V class matches highly conductive tap water with minimal line loss.
Electrocoagulation and metal recovery cells benefit from automatic reversal that strips deposited hydroxide sludge. In addition, electroplating rinse lines run periodic reverse to keep cathode plates free of dense copper and nickel scale. Consequently, plant crews extend plate service intervals and cut chemical cleaning cycles.
| Output Current | 2000 A (adjustable) |
|---|---|
| Output Voltage | 10 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
Heavy-Duty Electrocoagulation Rectifier from Gaohui Rectifier powers extra-large plate banks for continuous municipal and industrial effluent treatment. In addition, this 2000 A 24 V Heavy-Duty Electrocoagulation Rectifier matches high-flow channels that demand steady, ripple-free current. Consequently, operators scale floc formation without splitting current across multiple smaller rectifiers. Furthermore, Gaohui Rectifier reinforces the copper busbar for sustained high-current duty. As a result, the Heavy-Duty Electrocoagulation Rectifier holds turbidity, oil, and metal removal targets across 24/7 production.
Municipal wastewater pretreatment plants deploy this rectifier to drive extra-large aluminum and iron plate banks for phosphorus and turbidity reduction. For example, a 2000 A output sustains arrays treating thousands of cubic meters per hour. Moreover, the 24 V class matches typical plate gaps in high-flow channels.
Food, dairy, and slaughterhouses apply the same rectifier to break emulsified fats and settle suspended solids. In addition, metal finishing rinse water benefits from hydroxide flocs that capture dissolved nickel, copper, and zinc. Consequently, one rectifier covers primary, secondary, and emergency discharge duties on a continuous line.
| Output Current | 2000 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
High-Current Electrolytic Descaling Rectifier from Gaohui Rectifier suppresses calcium and silica scale on large cooling tower and heat-exchanger circuits. In addition, this 2000 A 30 V High-Current Electrolytic Descaling Rectifier drives high-current electrode arrays for industrial circulating water systems. Consequently, operators reduce chemical softening and acid wash frequency. Furthermore, Gaohui Rectifier holds ripple below 2% for even deposition on cathode plates. As a result, the High-Current Electrolytic Descaling Rectifier keeps heat-transfer surfaces clean across continuous plant operation.
Power plant and steel mill cooling tower loops deploy this rectifier to energize large cathode plates that precipitate scale out of circulating water. For example, a 2000 A output sustains arrays handling thousands of cubic meters per hour. Moreover, the 30 V class matches multi-stage electrode stacks typical of high-hardness makeup water.
Boiler feedwater and heat-exchanger circuits also benefit from the same rectifier, which prevents tube-wall scaling without adding acid. In addition, deep-well hard water and hot-water systems use it to suppress carbonate scale at the source. Consequently, plants cut chemical softening costs and extend heat-exchanger service life.
| Output Current | 2000 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrolytic descaling of hard-water circuits |
High-Power Electrocoagulation Rectifier from Gaohui Rectifier drives mega-scale plate banks for continuous high-flow effluent treatment. In addition, this 2000 A 30 V High-Power Electrocoagulation Rectifier suits municipal and industrial lines that demand extra headroom for stacked electrode arrays. Consequently, operators scale floc formation without stacking multiple smaller rectifiers. Furthermore, Gaohui Rectifier reinforces the copper busbar for sustained high-current duty. As a result, the High-Power Electrocoagulation Rectifier holds turbidity, oil, and metal removal targets across 24/7 production.
Mega municipal wastewater pretreatment plants deploy this rectifier to drive extra-large aluminum and iron plate banks for phosphorus and turbidity reduction. For example, a 2000 A output sustains arrays treating thousands of cubic meters per hour. Moreover, the 30 V class provides headroom for multi-stage electrode stacks with longer plate gaps.
Food, dairy, and slaughterhouses apply the same rectifier to break emulsified fats and settle suspended solids at high flow. In addition, metal finishing rinse water benefits from hydroxide flocs that capture dissolved nickel, copper, and zinc. Consequently, one rectifier covers primary, secondary, and emergency discharge duties on a continuous line.
| Output Current | 2000 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Automatic Reverse Periodic Rectifier from Gaohui Rectifier drives high-impedance electrolytic cells where fouling and scale threaten continuous operation. In addition, this 2000 A 60 V Automatic Reverse Periodic Rectifier swaps polarity on a programmable cycle to strip cathode deposits. Consequently, operators keep electrode gaps stable without manual scraping or acid baths. Furthermore, Gaohui Rectifier builds the reverse contactor with reinforced busbars for repeated high-current switching. As a result, the Automatic Reverse Periodic Rectifier sustains continuous operation in descaling, electrocoagulation, and metal recovery lines.
High-impedance electrolysis cells, such as stacked bipolar electrode arrays, use this rectifier to drive current through longer circuit gaps. For example, a 2000 A output at 60 V sustains large arrays with higher internal resistance. Moreover, the 60 V class provides headroom for sticky, viscous pollutant systems that demand high voltage.
Electrocoagulation and metal recovery cells benefit from automatic reversal that strips deposited hydroxide sludge. In addition, electroplating rinse lines run periodic reverse to keep cathode plates free of dense copper and nickel scale. Consequently, plant crews extend plate service intervals and cut chemical cleaning cycles.
| Output Current | 2000 A (adjustable) |
|---|---|
| Output Voltage | 60 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
High-Power Air-Cooled Electrocoagulation Rectifier from Gaohui Rectifier drives mega-scale plate banks for continuous high-conductivity effluent treatment. In addition, this 2500 A 12 V High-Power Air-Cooled Electrocoagulation Rectifier suits high-flow channels with short plate gaps and high conductivity. Consequently, operators scale floc formation without stacking multiple smaller rectifiers. Furthermore, Gaohui Rectifier reinforces the copper busbar for sustained high-current duty. As a result, the High-Power Air-Cooled Electrocoagulation Rectifier holds turbidity, oil, and metal removal targets across 24/7 production.
Mega municipal wastewater pretreatment plants deploy this rectifier to drive extra-large aluminum and iron plate banks for phosphorus and turbidity reduction. For example, a 2500 A output sustains arrays treating thousands of cubic meters per hour. Moreover, the 12 V class matches short plate gaps in highly conductive effluent with minimal line loss.
Food, dairy, and slaughterhouses apply the same rectifier to break emulsified fats and settle suspended solids at high flow. In addition, metal finishing rinse water benefits from hydroxide flocs that capture dissolved nickel, copper, and zinc. Consequently, one rectifier covers primary, secondary, and emergency discharge duties on a continuous line.
| Output Current | 2500 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
Electrocatalytic Drive Rectifier from Gaohui Rectifier drives mega-scale DSA anode reactors in continuous wastewater oxidation. In addition, this 3000 A 12 V Electrocatalytic Drive Rectifier carries a 24/7 continuous duty rating built for unattended plant operation. Consequently, engineers deploy it on chemical park terminal polishing and landfill leachate concentrate lines. Furthermore, Gaohui Rectifier reinforces the copper busbar to handle sustained ultra-high current without hot spots. As a result, the Electrocatalytic Drive Rectifier holds oxidation current stable across multi-shift production.
Chemical park end-of-pipe polishing stations use this rectifier to degrade residual COD before discharge. For example, a 3000 A output feeds large DSA anode stacks treating thousands of cubic meters per hour. Moreover, the 12 V class suits highly saline wastewater with high conductivity and short electrode gaps.
Landfill leachate concentrate and printed-circuit-board effluent also run the same rectifier for complex organic destruction. In addition, oilfield produced-water reuse lines apply it to oxidize residual hydrocarbons and control bacteria. Consequently, plants meet strict discharge limits without adding large chemical oxidation systems.
| Output Current | 3000 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU + HMI touch panel |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Duty Rating | Continuous 24/7 drive duty |
| DC Bus | Reinforced copper busbar |
Ultra-High-Current Electrocatalytic Rectifier from Gaohui Rectifier powers mega-scale DSA anode cells for terminal COD and ammonia removal. In addition, this 3000 A 15 V Ultra-High-Current Electrocatalytic Rectifier matches high-conductivity effluent with low resistive loss. Consequently, engineers deploy it on chemical park end-of-pipe and landfill leachate concentrate lines. Furthermore, Gaohui Rectifier reinforces the DC busbar for sustained ultra-high-current duty. As a result, the Ultra-High-Current Electrocatalytic Rectifier holds oxidation current stable across multi-shift operation.
Chemical park end-of-pipe polishing stations use this rectifier to degrade residual COD before discharge. For example, a 3000 A output feeds large DSA anode stacks treating thousands of cubic meters per hour. Moreover, the 15 V class suits highly saline wastewater with high conductivity and short electrode gaps.
Landfill leachate concentrate and printed-circuit-board effluent also run the same rectifier for complex organic destruction. In addition, oilfield produced-water reuse lines apply it to oxidize residual hydrocarbons and control bacteria. Consequently, plants meet strict discharge limits without adding large chemical oxidation systems.
| Output Current | 3000 A (adjustable) |
|---|---|
| Output Voltage | 15 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
Ultra-High-Current Electrocoagulation Rectifier from Gaohui Rectifier drives mega-scale plate banks for continuous high-flow effluent treatment. In addition, this 3000 A 18 V Ultra-High-Current Electrocoagulation Rectifier suits municipal and industrial lines that demand ultra-high current. Consequently, operators scale floc formation without stacking multiple smaller rectifiers. Furthermore, Gaohui Rectifier reinforces the copper busbar for sustained ultra-high-current duty. As a result, the Ultra-High-Current Electrocoagulation Rectifier holds turbidity, oil, and metal removal targets across 24/7 production.
Mega municipal wastewater pretreatment plants deploy this rectifier to drive extra-large aluminum and iron plate banks for phosphorus and turbidity reduction. For example, a 3000 A output sustains arrays treating thousands of cubic meters per hour. Moreover, the 18 V class matches typical plate gaps in high-flow channels.
Food, dairy, and slaughterhouses apply the same rectifier to break emulsified fats and settle suspended solids at high flow. In addition, metal finishing rinse water benefits from hydroxide flocs that capture dissolved nickel, copper, and zinc. Consequently, one rectifier covers primary, secondary, and emergency discharge duties on a continuous line.
| Output Current | 3000 A (adjustable) |
|---|---|
| Output Voltage | 18 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
N+1 Parallel Electrocoagulation Rectifier from Gaohui Rectifier drives mega-scale plate banks with built-in redundancy for continuous 24/7 effluent treatment. In addition, this 4000 A 24 V N+1 Parallel Electrocoagulation Rectifier combines four parallel modules with active load sharing. Consequently, a single module failure never stops the treatment line. Furthermore, Gaohui Rectifier links the modules over RS485 master-slave for automatic current redistribution. As a result, the N+1 Parallel Electrocoagulation Rectifier holds turbidity, oil, and metal removal targets across unattended operation.
Mega municipal wastewater pretreatment plants deploy this rectifier to drive extra-large aluminum and iron plate banks for phosphorus and turbidity reduction. For example, a 4000 A combined output sustains arrays treating thousands of cubic meters per hour. Moreover, the N+1 architecture lets maintenance crews swap modules without shutting the line down.
Food, dairy, and slaughterhouses apply the same rectifier to break emulsified fats and settle suspended solids at high flow. In addition, metal finishing rinse water benefits from hydroxide flocs that capture dissolved nickel, copper, and zinc. Consequently, one redundant package covers primary, secondary, and emergency discharge duties on a continuous line.
| Output Current | 4000 A (adjustable, N+1 parallel) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU (N+1 Sync) |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Redundancy | N+1 parallel with active load sharing |
| Parallel Link | RS485 master-slave |
| Application Duty | Electrocoagulation electrode arrays |
High-Current Air-Cooled Electrocatalytic Rectifier from Gaohui Rectifier powers mega-scale DSA anode cells for terminal COD and ammonia removal. In addition, this 4000 A 24 V High-Current Air-Cooled Electrocatalytic Rectifier matches high-conductivity effluent with low resistive loss. Consequently, engineers deploy it on chemical park end-of-pipe and landfill leachate concentrate lines. Furthermore, Gaohui Rectifier reinforces the DC busbar for sustained high-current duty. As a result, the High-Current Air-Cooled Electrocatalytic Rectifier holds oxidation current stable across multi-shift operation.
Chemical park end-of-pipe polishing stations use this rectifier to degrade residual COD before discharge. For example, a 4000 A output feeds mega-scale DSA anode stacks treating thousands of cubic meters per hour. Moreover, the 24 V class provides headroom for multi-stage electrode stacks with higher internal resistance.
Landfill leachate concentrate and printed-circuit-board effluent also run the same rectifier for complex organic destruction. In addition, oilfield produced-water reuse lines apply it to oxidize residual hydrocarbons and control bacteria. Consequently, plants meet strict discharge limits without adding large chemical oxidation systems.
| Output Current | 4000 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
N+1 Parallel Electrocatalytic Rectifier from Gaohui Rectifier powers mega-scale DSA anode cells with built-in redundancy for continuous 24/7 oxidation. In addition, this 4500 A 15 V N+1 Parallel Electrocatalytic Rectifier combines three parallel modules with active load sharing. Consequently, a single module failure never stops the treatment line. Furthermore, Gaohui Rectifier links the modules over RS485 master-slave for automatic current redistribution. As a result, the N+1 Parallel Electrocatalytic Rectifier holds oxidation current stable across unattended multi-shift operation.
Chemical park end-of-pipe polishing stations use this rectifier to degrade residual COD before discharge. For example, a 4500 A combined output feeds mega-scale DSA anode stacks treating thousands of cubic meters per hour. Moreover, the N+1 architecture lets maintenance crews swap modules without shutting the line down.
Landfill leachate concentrate and printed-circuit-board effluent also run the same rectifier for complex organic destruction. In addition, oilfield produced-water reuse lines apply it to oxidize residual hydrocarbons and control bacteria. Consequently, plants meet strict discharge limits without adding large chemical oxidation systems.
| Output Current | 4500 A (adjustable, N+1 parallel) |
|---|---|
| Output Voltage | 15 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU (N+1 Sync) |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Redundancy | N+1 parallel with active load sharing |
| Parallel Link | RS485 master-slave |
Ultra-High-Current Automatic Periodic Reverse Rectifier from Gaohui Rectifier drives mega-scale electrolytic cells where scale and fouling threaten continuous operation. In addition, this 5000 A 10 V Ultra-High-Current Automatic Periodic Reverse Rectifier swaps polarity on a programmable cycle to strip cathode deposits. Consequently, operators keep electrode gaps stable without manual scraping or acid baths. Furthermore, Gaohui Rectifier builds the reverse contactor with reinforced busbars for repeated ultra-high-current switching. As a result, the Ultra-High-Current Automatic Periodic Reverse Rectifier sustains continuous operation in mega descaling, electrocoagulation, and metal recovery lines.
Mega cooling tower and circulating water systems use this rectifier to suppress calcium and silica scale on cathode surfaces. For example, a 5000 A output feeds electrode arrays handling tens of thousands of cubic meters per hour. Moreover, the 10 V class matches highly conductive tap water with minimal line loss.
Electrocoagulation and metal recovery cells benefit from automatic reversal that strips deposited hydroxide sludge. In addition, electroplating rinse lines run periodic reverse to keep cathode plates free of dense copper and nickel scale. Consequently, plant crews extend plate service intervals and cut chemical cleaning cycles.
| Output Current | 5000 A (adjustable) |
|---|---|
| Output Voltage | 10 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
Water-Cooled Electrocatalytic Oxidation Rectifier from Gaohui Rectifier powers mega-scale DSA anode cells with the highest power density in the range. In addition, this 9000 A 24 V Water-Cooled Electrocatalytic Oxidation Rectifier combines four parallel modules with N+1 active load sharing. Consequently, a single module failure never stops the treatment line. Furthermore, Gaohui Rectifier uses closed-loop water cooling to hold junction temperatures steady in sealed machine rooms. As a result, the Water-Cooled Electrocatalytic Oxidation Rectifier sustains continuous ultra-high-current oxidation across multi-shift production.
Mega chemical park end-of-pipe polishing stations deploy this rectifier to degrade residual COD before discharge. For example, a 9000 A combined output feeds the largest DSA anode stacks treating tens of thousands of cubic meters per hour. Moreover, water cooling packs the high power density into a sealed machine room without external fan noise.
Landfill leachate concentrate and industrial integrated wastewater terminal treatment lines also run the same rectifier. In addition, oilfield produced-water reuse stations apply it to oxidize residual hydrocarbons at mega flow. Consequently, plants meet strict discharge limits without adding large chemical oxidation systems.
| Output Current | 9000 A (adjustable, N+1 parallel) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Water Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU (N+1 Sync) |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Redundancy | N+1 parallel with active load sharing |
| Parallel Link | RS485 master-slave |
Air-Cooled High-Voltage Electrocoagulation Rectifier from Gaohui Rectifier drives series-connected electrode arrays for high-impedance effluent streams. In addition, this 30 A 500 V Air-Cooled High-Voltage Electrocoagulation Rectifier suits long plate strings where water resistance demands elevated working voltage. Therefore, operators choose the Air-Cooled High-Voltage Electrocoagulation Rectifier for leachate pretreatment and low-conductivity textile wastewater. Furthermore, air cooling removes any need for chilled water circuits inside the skid. As a result, plant engineers fit the rectifier into compact electrical rooms without cooling-tower tie-ins.
Leachate pretreatment stations deploy this rectifier to drive long series plate strings that resist high-ohmic wastewater. For example, 30 A at 500 V energizes a stacked electrode bank handling 5–10 m³/h of low-conductivity raw leachate. Moreover, the high-voltage ceiling keeps line losses low across elongated reactor headers.
Municipal tertiary plants run the same rectifier on electrocoagulation polishing steps that target residual phosphorus and turbidity. In addition, surface-treatment shops use it for dilute rinse streams where high cell voltage overcomes poor conductivity. Consequently, engineers cover two very different pretreatment duties with one air-cooled frame.
| Output Current | 30 A (adjustable) |
|---|---|
| Output Voltage | 500 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
| DC Output Rating | 15 kW continuous |
Compact Electrocatalytic Rectifier from Gaohui Rectifier powers small titanium-anode cells for laboratory and pilot oxidation duty. In addition, this 100 A 6 V Compact Electrocatalytic Rectifier fits tightly into bench-top and skid-mounted treatability rigs. Therefore, researchers pick the Compact Electrocatalytic Rectifier when electrode area stays modest but current ripple must stay low. Furthermore, the 6 V ceiling matches highly conductive synthetic baths without stressing seals. As a result, the rectifier supports reliable hydroxyl-radical screening during formulation trials.
University and in-house R&D labs use this rectifier to bench-test dimensionally stable anodes on dye intermediate wastewater. For example, 100 A at 6 V energizes a small flow-through cell treating 0.5–2 m³/h of simulated effluent. Moreover, the low voltage keeps bath heating modest during overnight runs.
Small plating shops run the same rectifier as a polishing power block on dilute rinse water loops. In addition, contract water-treatment labs deploy it to validate electrocatalytic oxidation before scaling to production. Consequently, one compact frame covers both treatability studies and light commercial duty.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 6 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| Enclosure | Compact wall-mount chassis |
Electrocatalytic Oxidation Water Treatment Rectifier from Gaohui Rectifier feeds small-to-medium anode packs with stable low-voltage DC. In addition, this 100 A 12 V Electrocatalytic Oxidation Water Treatment Rectifier suits plating rinse loops and pharmaceutical pretreatment skids. Therefore, process engineers select the Electrocatalytic Oxidation Water Treatment Rectifier when electrode area grows but bath conductivity stays high. Furthermore, RS485 control allows remote setpoint tuning as COD load swings between shifts. As a result, the rectifier holds oxidation current steady without manual intervention.
Printed-circuit-board shops use this rectifier to break metal-complex brighteners in dilute rinse water before biological treatment. For example, 100 A at 12 V drives a compact anode pack handling 3–8 m³/h of conductive rinse flow. Moreover, the low voltage keeps cell voltage margins safe against electrode passivation.
Pharmaceutical pilot plants run the same rectifier on advanced oxidation steps that target residual antibiotics. In addition, contract treatability labs deploy it to screen anode coatings on real factory samples. Consequently, operators bridge lab-scale screening and small production polishing with one air-cooled frame.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 1.2 kW continuous |
Compact Electrocoagulation Rectifier from Gaohui Rectifier drives small plate arrays for on-site effluent polishing. In addition, this 100 A 12 V Compact Electrocoagulation Rectifier suits pilot skids and packaged treatment lines where floor space stays tight. Therefore, plant supervisors choose the Compact Electrocoagulation Rectifier for turbidity, oil, and trace-metal removal in high-conductivity water. Furthermore, air cooling removes cooling-water plumbing from the package. As a result, the rectifier slots into existing pump rooms without major civil work.
Food and dairy processors use this rectifier to break emulsified fats and settle suspended solids before dissolved-air flotation. For example, 100 A at 12 V energizes a compact aluminum plate stack handling 5–15 m³/h of wash-water. Moreover, the low voltage class keeps operator contact hazards low during plate replacement.
Plating shops run the same rectifier on rinse loops that require hydroxide flocculation of dissolved nickel and copper. In addition, municipal satellite plants pilot phosphorus-removal plate banks at bench-to-demonstration scale. Consequently, engineers cover pretreatment polishing, pilot trials, and emergency bypass duties with one chassis.
| Output Current | 100 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
| Enclosure | Compact floor-standing cabinet |
Sodium Hypochlorite Electrolysis Rectifier from Gaohui Rectifier feeds on-site brine electrolysis cells for low-concentration disinfection. In addition, this 175 A 24 V Sodium Hypochlorite Electrolysis Rectifier suits small municipal plants and rural water stations that avoid bulk chemical deliveries. Therefore, operators select the Sodium Hypochlorite Electrolysis Rectifier for safer, on-demand hypochlorite generation. Furthermore, RS485 control ties current output to daily chlorine demand curves. As a result, the rectifier cuts trucked bleach usage while keeping residual targets on target.
Township water plants use this rectifier to power brine electrolyzers that produce 0.8% sodium hypochlorite on site. For example, 175 A at 24 V drives a mid-size chlorination skid dosing 50–200 m³/day of potable water. Moreover, air cooling removes chilled-water loops from remote pump stations.
Swimming-park and seafood-processing sites run the same rectifier for CIP disinfection loops that replace trucked sodium hypochlorite. In addition, industrial cooling towers use the output for chlorine-based biofouling control. Consequently, engineers consolidate disinfection duties across municipal, recreational, and food-grade sites with one chassis.
| Output Current | 175 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Sodium hypochlorite generation cells |
| DC Output Rating | 4.2 kW continuous |
High-Voltage Electrocatalytic Oxidation Rectifier from Gaohui Rectifier drives stacked anode packs for low-conductivity industrial effluents. In addition, this 250 A 120 V High-Voltage Electrocatalytic Oxidation Rectifier suits leachate concentrate and chemical-plant tail water where cell resistance climbs. Therefore, process engineers specify the High-Voltage Electrocatalytic Oxidation Rectifier when low-voltage cabinets fail to push sufficient current. Furthermore, RS485 control lets operators track voltage drift as foulant builds on electrodes. As a result, the rectifier sustains oxidation throughput without manual tap changes.
Landfill leachate concentrate lines use this rectifier to energize multi-stage anode stacks that target refractory COD after reverse-osmosis. For example, 250 A at 120 V feeds a series of dimensionally stable anode cells treating 10–30 m³/h. Moreover, the elevated voltage overcomes high-ohmic brine without overheating short busbars.
Chemical-park final polishing stations run the same rectifier on mixed industrial wastewater before discharge. In addition, dye and pharmaceutical plants deploy it for advanced oxidation on low-conductivity intermediates. Consequently, engineers cover leachate concentrate, chemical tail water, and dye streams with one air-cooled cabinet.
| Output Current | 250 A (adjustable) |
|---|---|
| Output Voltage | 120 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 30 kW continuous |
Auto-Reverse Electrocatalytic Rectifier from Gaohui Rectifier periodically swaps polarity to strip fouling films from oxidation anodes. In addition, this 250 A 120 V Auto-Reverse Electrocatalytic Rectifier targets low-conductivity effluents that foul standard anode surfaces within weeks. Therefore, maintenance crews choose the Auto-Reverse Electrocatalytic Rectifier to extend anode life without manual acid washes. Furthermore, programmable dwell time lets chemists balance cleaning cycles against oxidation throughput. As a result, the rectifier runs continuously even on oily or scaling waste streams.
Oily refinery and petrochemical wastewater lines use this rectifier to oxidize emulsified hydrocarbons while reversing polarity to strip oily films. For example, 250 A at 120 V drives a series anode pack handling 15–40 m³/h of scaling effluent. Moreover, the reverse cycle lifts carbonate and soap deposits that normally choke cell voltage.
Mining leachate and flue-gas scrubber bleed streams run the same rectifier on advanced polishing steps where mineral salts precipitate. In addition, contract oxidation plants deploy it when anode fouling forces weekly manual cleaning. Consequently, engineers cut service shutdowns and keep discharge limits stable across seasons.
| Output Current | 250 A (adjustable) |
|---|---|
| Output Voltage | 120 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
High-Voltage Automatic Reverse Rectifier from Gaohui Rectifier swaps electrode polarity on a programmable timer to strip scale and deposits. In addition, this 250 A 150 V High-Voltage Automatic Reverse Rectifier drives long series electrolytic stacks in low-conductivity water. Therefore, plant engineers specify the High-Voltage Automatic Reverse Rectifier for cells that foul fast under continuous duty. Furthermore, RS485 control lets operators adjust reversal period remotely as water chemistry changes. As a result, the rectifier keeps both current density and plate lifetime in balance.
Electrolytic descaling loops on cooling towers use this rectifier to reverse polarity and strip cathode calcium carbonate deposits. For example, 250 A at 150 V feeds a multi-stack electrode array serving 100–300 m³/h circulation systems. Moreover, the elevated voltage overcomes scaling films that otherwise push cell voltage out of range.
Electrocoagulation pretreatment on landfill leachate runs the same rectifier to balance plate consumption across both electrodes. In addition, copper-electrowinning pilot cells deploy it to reduce manual plate flipping. Consequently, maintenance teams cut acid-wash shutdowns while holding treatment throughput steady.
| Output Current | 250 A (adjustable) |
|---|---|
| Output Voltage | 150 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
| DC Output Rating | 37.5 kW continuous |
High-Voltage Electrocatalytic Rectifier from Gaohui Rectifier energizes long series anode strings for very low-conductivity effluent. In addition, this 250 A 300 V High-Voltage Electrocatalytic Rectifier suits reverse-osmosis concentrate and distillery wastewater that defeats ordinary low-voltage cabinets. Therefore, process engineers choose the High-Voltage Electrocatalytic Rectifier when ohmic cell losses demand extra headroom. Furthermore, RS485 monitoring flags voltage creep as electrodes foul between service stops. As a result, the rectifier sustains hydroxyl-radical output through long unattended runs.
Landfill leachate reverse-osmosis concentrate lines use this rectifier to drive stacked dimensionally stable anodes on refractory COD. For example, 250 A at 300 V feeds a long series cell bank treating 10–25 m³/h of high-ohmic concentrate. Moreover, the high-voltage ceiling cuts line-current losses across elongated reactor headers.
Distillery and fermentation plants run the same rectifier on spent-grain syrup wastewater that carries low salt but high organic load. In addition, chemical-park final polishing uses it to push conductivity-deficient streams to discharge limits. Consequently, engineers cover RO concentrate, distillery waste, and chemical tail water with one air-cooled frame.
| Output Current | 250 A (adjustable) |
|---|---|
| Output Voltage | 300 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 75 kW continuous |
Electrocatalytic Water Treatment Rectifier from Gaohui Rectifier powers flat titanium-anode beds for high-conductivity industrial wastewater. In addition, this 300 A 12 V Electrocatalytic Water Treatment Rectifier suits plating and circuit-board rinse loops where bath conductivity stays high. Therefore, operators pick the Electrocatalytic Water Treatment Rectifier for steady hydroxyl-radical generation without chemical oxidants. Furthermore, the low-voltage, high-current design minimizes insulation demands on the cell skid. As a result, the rectifier slots into existing finishing lines with simple busbar hooks.
Printed-circuit-board shops use this rectifier to break metal-complex brighteners and oxidize residual organics in dilute rinse water. For example, 300 A at 12 V feeds a multi-cell anode bed handling 10–25 m³/h of highly conductive rinse flow. Moreover, the low voltage keeps stray-current heating modest in narrow plating trenches.
Electroplating surface-treatment lines run the same rectifier as an advanced-oxidation step before ion-exchange polishing. In addition, metal-finishing contract plants deploy it to lower COD discharge permits without adding chemical dosing tanks. Consequently, engineers consolidate rinse-water polishing and permit compliance in one air-cooled cabinet.
| Output Current | 300 A (adjustable) |
|---|---|
| Output Voltage | 12 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 3.6 kW continuous |
Sodium Hypochlorite Water Treatment Rectifier from Gaohui Rectifier drives mid-size brine electrolyzers for on-site low-concentration chlorination. In addition, this 300 A 30 V Sodium Hypochlorite Water Treatment Rectifier suits municipal water plants that replace delivered bleach with on-site generation. Therefore, disinfection crews choose the Sodium Hypochlorite Water Treatment Rectifier to cut chemical logistics and storage hazards. Furthermore, RS485 control ties current output to daily chlorine demand curves. As a result, the rectifier delivers consistent residual while trimming off-hours energy waste.
Municipal water treatment plants use this rectifier to power brine electrolysis skids producing 0.8% sodium hypochlorite on site. For example, 300 A at 30 V drives a mid-size chlorination system serving 2,000–8,000 m³/day of potable water. Moreover, air cooling fits unmanned pump houses that lack chilled-water connections.
Industrial cooling towers and seafood-processing CIP stations run the same rectifier for continuous low-dose disinfection. In addition, remote mining camps deploy it where bulk chemical deliveries stay expensive. Consequently, engineers cover municipal, industrial, and remote-site chlorination duties with one chassis.
| Output Current | 300 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Sodium hypochlorite generation cells |
| DC Output Rating | 9 kW continuous |
Three-Dimensional Electrocatalytic Rectifier from Gaohui Rectifier energizes packed particle-electrode beds for intensified oxidation. In addition, this 300 A 40 V Three-Dimensional Electrocatalytic Rectifier suits high-salt, high-COD chemical wastewater that overwhelms flat-plate cells. Therefore, process engineers specify the Three-Dimensional Electrocatalytic Rectifier when surface area per reactor volume must climb. Furthermore, RS485 control lets operators tune current as particle bed resistance shifts with fouling. As a result, the rectifier raises hydroxyl-radical output within a compact reactor footprint.
Chemical-park wastewater plants use this rectifier to drive packed particle-electrode beds on high-COD brines after biological treatment. For example, 300 A at 40 V feeds a three-dimensional cell treating 15–40 m³/h of saline tail water. Moreover, the expanded electrode area cuts required residence time versus flat-plate stacks.
Electroplating and circuit-board lines run the same rectifier on split streams that concentrate metal-complex organics before discharge. In addition, landfill leachate polishing stations deploy it to push refractory COD toward reuse limits. Consequently, engineers cover chemical brines, plating concentrates, and leachate polishing with one air-cooled frame.
| Output Current | 300 A (adjustable) |
|---|---|
| Output Voltage | 40 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| Electrode Support | Three-dimensional (particle) electrode cells |
| DC Output Rating | 12 kW continuous |
Electrocatalytic Rectifier from Gaohui Rectifier powers mid-size dimensionally stable anode banks on continuous treatment lines. In addition, this 500 A 24 V Electrocatalytic Rectifier suits plating, dye, and pharmaceutical wastewater that needs steady hydroxyl-radical output. Therefore, plant operators choose the Electrocatalytic Rectifier as the workhorse of multi-cell oxidation skids. Furthermore, RS485 control allows setpoint changes from the central control room. As a result, the rectifier holds current within tight bands as organic load swings between batches.
Dye and textile finishing plants use this rectifier to oxidize residual color and refractory COD after biological treatment. For example, 500 A at 24 V feeds a multi-cell anode bed handling 30–80 m³/h of conductive dye effluent. Moreover, the mid-voltage class balances current density and insulation cost across long electrode strings.
Pharmaceutical intermediate plants run the same rectifier on advanced oxidation steps targeting residual antibiotics. In addition, circuit-board shops deploy it as a polishing stage before ion-exchange recovery. Consequently, engineers consolidate dye, pharma, and plating polishing duties on one cabinet platform.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 24 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 12 kW continuous |
Automatic Periodic Reverse Electrocatalytic Rectifier from Gaohui Rectifier swaps polarity on a timer to strip fouling films from oxidation anodes. In addition, this 500 A 30 V Automatic Periodic Reverse Electrocatalytic Rectifier targets oily, scaling effluents that foul flat-plate cells within weeks. Therefore, maintenance crews pick the Automatic Periodic Reverse Electrocatalytic Rectifier to stretch anode service intervals. Furthermore, programmable dwell time balances cleaning cycles against oxidation throughput. As a result, the rectifier runs continuously even on difficult refinery and petrochemical streams.
Refinery and petrochemical wastewater lines use this rectifier to oxidize emulsified hydrocarbons while reversing polarity to strip oily biofilms. For example, 500 A at 30 V feeds a multi-cell anode array handling 40–100 m³/h of scaling effluent. Moreover, the reverse cycle lifts soap and carbonate deposits that normally push cell voltage out of range.
Coking-plant and dye-intermediate streams run the same rectifier on advanced polishing steps where mineral salts precipitate. In addition, contract oxidation stations deploy it when anode fouling forces weekly manual acid washes. Consequently, engineers cut service shutdowns while holding discharge limits stable across seasons.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
Periodic Reverse Rectifier from Gaohui Rectifier swaps electrode polarity on a programmable cycle to balance plate wear. In addition, this 500 A 36 V Periodic Reverse Rectifier suits electrocoagulation and electrolytic cells that scale or foul under continuous one-way current. Therefore, plant engineers specify the Periodic Reverse Rectifier to extend electrode life without manual flipping. Furthermore, RS485 control lets operators tune reversal period as feed-water chemistry shifts. As a result, the rectifier keeps floc quality and descaling effect stable across long unattended runs.
Electrocoagulation pretreatment stations use this rectifier to balance consumption of aluminum or iron plates across both polarities. For example, 500 A at 36 V drives a plate bank handling 50–120 m³/h of food, textile, or plating effluent. Moreover, the periodic reverse action strips hydroxide films that would otherwise insulate the cathode surface.
Electrolytic descaling loops on cooling towers run the same rectifier to lift calcium carbonate deposits from cathode plates automatically. In addition, surface-treatment shops deploy it on rinse-water flocculation that suffers from uneven plate wear. Consequently, maintenance teams cut acid-wash shutdowns while holding floc quality steady.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 36 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Reversal Period | Adjustable (e.g., 10 s–30 min) |
| Polarity Switching | Automatic with programmable dwell time |
| DC Output Rating | 18 kW continuous |
Air-Cooled Electrocatalytic Water Treatment Rectifier from Gaohui Rectifier drives multi-stage anode banks on industrial oxidation lines. In addition, this 500 A 50 V Air-Cooled Electrocatalytic Water Treatment Rectifier suits chemical-park tail water and leachate polishing that needs moderate voltage headroom. Therefore, process engineers choose the Air-Cooled Electrocatalytic Water Treatment Rectifier when bath conductivity sits in the mid range. Furthermore, RS485 control lets operators adjust setpoints as COD load swings between batches. As a result, the rectifier holds oxidation throughput steady without manual trim.
Chemical-park final polishing stations use this rectifier to push mixed industrial wastewater toward discharge limits after biological treatment. For example, 500 A at 50 V feeds a multi-cell anode array handling 40–100 m³/h of mid-conductivity tail water. Moreover, the 50 V class reaches longer electrode strings without stepping up to high-voltage cabinets.
Landfill leachate polishing plants run the same rectifier on advanced oxidation steps targeting refractory COD. In addition, dye and pharmaceutical intermediate streams deploy it to lower residual color before reuse. Consequently, engineers cover chemical tail water, leachate polishing, and dye streams with one air-cooled platform.
| Output Current | 500 A (adjustable) |
|---|---|
| Output Voltage | 50 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 25 kW continuous |
Air-Cooled Electrocatalytic Treatment Rectifier from Gaohui Rectifier drives expanded anode banks on continuous industrial oxidation lines. In addition, this 600 A 30 V Air-Cooled Electrocatalytic Treatment Rectifier suits chemical-park and dye wastewater that needs steady high-current output. Therefore, plant engineers choose the Air-Cooled Electrocatalytic Treatment Rectifier as a workhorse for mid-to-large treatment skids. Furthermore, RS485 control ties setpoints to upstream flow and pH signals. As a result, the rectifier holds oxidation throughput stable as organic load swings between shifts.
Dye and textile finishing plants use this rectifier to oxidize residual color and refractory COD after biological treatment. For example, 600 A at 30 V feeds a multi-cell anode array handling 50–120 m³/h of conductive dye effluent. Moreover, the 30 V class balances current density and insulation cost across long electrode strings.
Landfill leachate polishing stations run the same rectifier on advanced oxidation steps targeting refractory organics. In addition, circuit-board shops deploy it as a polishing stage before ion-exchange recovery. Consequently, engineers cover dye effluent, leachate polishing, and plating rinse on one cabinet platform.
| Output Current | 600 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 18 kW continuous |
Air-Cooled Electrocatalytic Oxidation Water Treatment Rectifier from Gaohui Rectifier powers large multi-cell anode arrays on heavy-duty oxidation lines. In addition, this 800 A 30 V Air-Cooled Electrocatalytic Oxidation Water Treatment Rectifier suits chemical-park and pharmaceutical wastewater at industrial flow rates. Therefore, process engineers specify the Air-Cooled Electrocatalytic Oxidation Water Treatment Rectifier when treatment volume climbs beyond skid scale. Furthermore, RS485 control allows centralized monitoring across a whole treatment train. As a result, the rectifier delivers steady hydroxyl-radical output for 24/7 operation.
Chemical-park central wastewater plants use this rectifier to drive multi-stage anode beds on combined industrial effluent. For example, 800 A at 30 V feeds a large oxidation array handling 80–200 m³/h of mid-conductivity tail water. Moreover, the high-current class reduces the number of parallel cabinets needed per train.
Pharmaceutical and fine-chemical plants run the same rectifier on advanced oxidation steps targeting residual antibiotics and intermediates. In addition, landfill leachate treatment stations deploy it for final polishing before discharge. Consequently, engineers consolidate park-scale oxidation, pharma polishing, and leachate duties on one air-cooled platform.
| Output Current | 800 A (adjustable) |
|---|---|
| Output Voltage | 30 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 24 kW continuous |
High-Current Electrocatalytic Treatment Rectifier from Gaohui Rectifier powers heavy-duty anode arrays on industrial-scale oxidation trains. In addition, this 1300 A 26 V High-Current Electrocatalytic Treatment Rectifier suits chemical-park and leachate lines that treat hundreds of cubic meters per hour. Therefore, plant engineers specify the High-Current Electrocatalytic Treatment Rectifier when parallel mid-size cabinets would multiply control points. Furthermore, RS485 master-slave links keep multiple rectifiers in step across one oxidation train. As a result, the rectifier delivers steady high-current DC for continuous 24/7 duty.
Chemical-park central treatment plants use this rectifier to drive expanded anode beds on combined industrial effluent at park scale. For example, 1300 A at 26 V feeds a large oxidation array handling 150–400 m³/h of mid-conductivity tail water. Moreover, the high-current class cuts parallel-cabinet count and simplifies busbar work.
Landfill leachate treatment stations run the same rectifier on advanced oxidation trains that target refractory COD. In addition, large textile dyeing complexes deploy it for final color removal after biological treatment. Consequently, engineers cover park-scale oxidation, leachate polishing, and dye finishing on one air-cooled platform.
| Output Current | 1300 A (adjustable) |
|---|---|
| Output Voltage | 26 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocatalytic oxidation cells |
| DC Output Rating | 34 kW continuous |
Air-Cooled High-Current Electrocoagulation Rectifier from Gaohui Rectifier powers large plate arrays on industrial-scale flocculation trains. In addition, this 2000 A 20 V Air-Cooled High-Current Electrocoagulation Rectifier suits food, textile, and municipal wastewater that treats hundreds of cubic meters per hour. Therefore, plant engineers choose the Air-Cooled High-Current Electrocoagulation Rectifier when parallel mid-size cabinets would multiply control points. Furthermore, RS485 master-slave links keep multiple cabinets in step across one flocculation train. As a result, the rectifier delivers steady high-current DC for 24/7 duty.
Large food and dairy processors use this rectifier to drive broad plate arrays on wash-water streams that carry emulsified fats. For example, 2000 A at 20 V feeds a multi-bank electrode rack handling 200–500 m³/h of high-conductivity process water. Moreover, the high-current class cuts parallel-cabinet count and simplifies busbar work.
Municipal industrial parks run the same rectifier on electrocoagulation pretreatment that targets combined turbidity, oil, and trace metals. In addition, textile dyeing complexes deploy it for color and COD reduction before biological treatment. Consequently, engineers cover food wastewater, park pretreatment, and textile flocculation on one air-cooled platform.
| Output Current | 2000 A (adjustable) |
|---|---|
| Output Voltage | 20 V (adjustable) |
| Cooling | Air Cooled |
| Input | 3-Phase 380 V AC ±10%, 50/60 Hz |
| Ripple | ≤2% |
| Efficiency | ≥90% |
| Control Interface | RS485 Modbus RTU |
| Protection | Overcurrent, Overvoltage, Overtemperature, Short-Circuit |
| Application Duty | Electrocoagulation electrode arrays |
| DC Output Rating | 40 kW continuous |